Without one every c7200 busy-waits a full CPU core for the whole scenario -- the tests create raw nodes and no template supplies a value (measured: constant ~100 % per router, up to ~6 minutes per dynamips scenario). harness.dynamips_idlepc() detects a value through the controller's auto_idlepc endpoint (the GUI idle-PC finder path: a throwaway project boots the image, candidate values are validated by measuring actual CPU usage) and caches it in ~/.cache/gns3-e2e/idlepc.json keyed by the image checksum, so the cost (~100 s here) is paid once per image, not per run. GNS3_E2E_IDLEPC overrides detection; any failure returns None and the scenarios run without one rather than fail on a CPU optimisation. All four scenarios that boot c7200 routers (dynamips kernel/relay, ethernet switch kernel/relay) pass the value at creation. Live: detected 0x60189234 for the M11 image (238 s first run including detection); the routers drop from ~100 % during boot to 3-8 % steady (sampled per process), and a re-run reports the cached value with no detection.
3.7 KiB
Live end-to-end tests
Tests under this directory run against a real server: real uBridge, real
kernel interfaces (privileged), real emulator binaries and real images. They
verify what unit tests cannot — that a datapath actually forwards traffic,
that kernel bridges actually enslave anchors, that tc impairments actually
shape packets. They are marked e2e and excluded from normal test runs
(see tests/pytest.ini); run them explicitly:
pytest -m e2e tests/e2e -s # -s shows the progress prints
pytest -m e2e tests/e2e -k dynamips # one scenario
Two run modes, chosen per test through harness.live_server(kernel=...):
- Target an existing server — set
GNS3_E2E_URL(e.g.http://127.0.0.1:3080/v3, plusGNS3_E2E_USER/GNS3_E2E_PASSWORD, default admin/admin). The server must already be configured for the datapath under test (kernel links needenable_kernel_datapath = True). - Isolated instance (the default) — the harness starts its own server
process on a free port with its own config directory (the controller DB
and every path follow the config), so nothing on the machine is touched.
It needs
ubridge,dynamipsand an images directory (GNS3_E2E_IMAGES, default~/GNS3/images) available locally.
Either way each test creates its own project and deletes it again. Set
GNS3_E2E_KEEP=1 to keep the project (and a started instance) on failure
and print where to look at it.
The dynamips scenarios give their routers an idle-PC: detected once per
image through the controller's auto_idlepc (a throwaway project and a
real CPU-usage measurement — the GUI's idle-PC finder path) and cached in
~/.cache/gns3-e2e/idlepc.json keyed by the image checksum. Without one,
each c7200 burns a full CPU core for the whole scenario — the e2e
creates raw nodes, so no template supplies a value. Set GNS3_E2E_IDLEPC
to skip the detection and use the given value (detection failing is never
fatal: the routers simply run without one).
harness.py holds the shared pieces — REST client, server lifecycle, the
IOS console driver, host-side kernel inspections (bridge membership, tap
admin state, tc qdiscs, the L2-anchor spec §E assertions) — so a new node
type adds only its own scenario module.
Current scenarios:
test_dynamips_kernel_datapath.py— two real c7200 routers: kernel link (anchors, per-link bridge, netem delay, suspend, capture, delete/re-create, stop/start) plus a serial link staying on the relay, and a negative control on an isolated relay-configured instance.test_ethernet_switch_kernel_datapath.py— a real Ethernet switch (kernel bridge) between two c7200 routers: deferred joins on boot, VLAN isolation, absorbed-anchor filters/suspend/capture, VPCS peers staying on the relay, and a relay negative control.test_iol_docker_kernel_datapath.py— two real iol-xe containers (Cisco CML iol-runner images): kernel link through the port bridge's swappable TAP leg (anchors at start, netem delay, suspend, capture, link delete/re-create swap, node stop/start rewiring) and a relay negative control.
Every kernel scenario also asserts the L2-anchor spec's server-side
guarantees (docs/design/ubridge-l2-anchor-spec.md §E): anchors and bridges
carry no L3 identity (assert_pure_l2), joined ports are FORWARDING
(assert_forwarding), and — in the Dynamips suite — an idle link with the
guests silenced stays silent for 5 s (assert_idle_silence). These skip on
a uBridge without link l2only (probed once by harness.l2only_supported()).
Set GNS3_E2E_DEBUG=1 to run the isolated instance with debug logging (the
uBridge command stream lands in its server.log).