YueGuobin c63b2e3e14 docs(mcp): node_console_exec — QEMU serial getty login needs one call
Field finding from the smoke test: login flushes typed-ahead input
before printing "Password: ", so a password sent in a separate call is
lost (Login incorrect loop). Sending username and password in the same
command string logs in reliably; the shell then persists across calls.