Markers now work on serial links (Cisco HDLC / PPP / Frame Relay / ATM), not just Ethernet. A marker carries a data_link_type (default DLT_EN10MB); at the uBridge boundary it becomes the 'mark ... linktype <dlt>' keyword so the BPF compiles and the pcap is written with the matching link-layer.
- MarkerCreate / MarkerDefinitionCreate gain data_link_type (default DLT_EN10MB). Per-link it is create-only; definitions are updatable (a change re-fans-out).
- base_node._marker_linktype() normalizes the GNS3 DLT name (strip DLT_, uppercase, None for EN10MB). Single source is SerialPort.data_link_types, so Cisco PPP -> PPP_SERIAL (50), matching the capture path -- no second mapping table.
- _ubridge_add_marker_filter (generic) and the IOU marker loop append 'linktype <dlt>'.
- Definition fan-out branches on link_type in inherit_marker: Ethernet is always EN10MB; a serial link uses the definition's WAN encapsulation, or is SKIPPED when none was chosen (an EN10MB pcap on serial is undecodable). One definition covers a mixed topology.
- MCP marker_definition exposes data_link_type (None = not forwarded).
- No uBridge rebuild on a data_link_type change -- only that one marker's filter is swapped (delete + re-add), mirroring a BPF change; reset_packet_filters preserves sibling mark filters.
Requires the uBridge build with 'mark ... linktype' support.
A marker definition fans out to every link and auto-selects its capture node
on each, so tx/rx is relative to a node that varies per link — the controller
already rejects it (409). Exposing direction on the MCP definition tool let an
agent ask for something that could only fail. Remove the parameter and the
handler's direction handling; the docstring now points to encoding direction in
the BPF (e.g. 'icmp and icmp[icmptype]==8'). Per-link link_marker keeps
direction, where the capture node is fixed.
direction was settable but not clearable: once a marker or project-level
definition had direction=tx/rx, no update path could return it to "both
directions", and the definition-sync fan-out silently kept stale values on
every inherited copy.
Introduce a _UNSET sentinel (link.py) distinct from None so updaters can
tell "caller omitted direction" (preserve) from "caller passed None"
(clear). Thread it through UDPLink.update_marker and
Project.update_marker_definition; the two REST routes use Pydantic v2
model_fields_set to translate an explicit JSON null into the sentinel.
MCP follows with a "both" token: link_marker / marker_definition handlers
map direction="both" to a null in the REST body (tri-state: omit=preserve,
tx/rx=set, both=clear), and the tool descriptions/docstrings document it.
Backward compatible: omitting direction or passing tx/rx behaves exactly
as before; only an explicit null / "both" clears.
A marker is single-sided — only the chosen capture node's uBridge installs the
mark filter — and dir=tx|rx is interpreted from that node's perspective. Until
now the observer was always auto-picked (_choose_marker_side), so dir=tx meant
"the auto-chosen endpoint is sending", which is unpredictable and makes the
direction filter hard to render meaningfully in the Web UI.
Add an optional create-only capture_node_id to MarkerCreate: when set, the
marker is pinned to that endpoint's uBridge (validated as a link endpoint and a
marker-capable type); when omitted, behavior is unchanged (auto-pick). The
chosen id is already echoed back as capture_node_id and in MARK signals, so the
UI can always render the observer regardless of who picked it.
capture_node_id is create-only (changing it would silently flip the meaning of
stored direction; recreate instead) and is not accepted on project-level
definitions — they are link-agnostic and have no endpoints, so inherited
markers keep auto-picking per link.
Plumbed through REST create_marker, the MCP link_marker tool, and base
Link.start_marker. update_marker does not forward it.
Direction field in marker.match events
=======================================
Read ubridge dir=<tx|rx> from MARK signal datagrams and forward it
as a "dir" key in the marker.match notification event. The field is
additive -- older ubridge builds omit it and the parser leaves it null,
so consumers fall back to undirected rendering with no version coupling.
Semantics are relative to the capture node (the signal's node=<id>):
tx = capture node is sending (ingressed device-side NIO), rx = it is
receiving (ingressed link-side NIO).
Per-marker direction filter (opt-in, server-side pipeline)
==========================================================
Add a direction field to MarkerCreate and MarkerDefinitionCreate
schemas ("tx" | "rx" | null). Plumb it through the full pipeline:
Schema -> controller (start_marker/update_marker, marker_entry,
_markers_for_node, update_marker_definition sync)
-> REST/MCP handlers -> compute _ubridge_add_marker_filter +
IOU _ubridge_apply_markers -> bridge add_packet_filter dir <tx|rx>
When set, ubridge only fires the mark handler (signal + pcap) for
packets matching the chosen direction. null (default/legacy) = both
directions -- zero behavioural change for existing markers.
Docs and tests
==============
- docs/features/marker-traffic-insight.md: signal format updated,
new Direction section with NIO mapping, arrow mapping, and additive
compatibility note.
- tests/compute/marker/test_marker_manager.py: 3 new parser tests
(dir tx/rx/absent) plus existing test extended to assert dir=None.
13 files, +123/-22, 72 tests pass (zero breakage)
For Docker nodes, reload bottoms out as a raw POST /containers/{id}/restart
to the Docker daemon, bypassing GNS3's start/stop lifecycle (uBridge
re-attach, console servers, NIC setup). The container restarts at the
Docker level but GNS3's plumbing goes out of sync, and the daemon call can
block up to the controller's 240s timeout — manifesting as "reload hangs /
no response". stop+start runs the full lifecycle and is reliable.
Remove the node_reload and node_reload_all MCP tools (tool functions,
handlers, NODE_TOOLS entry, tests, docs). The underlying REST endpoints
(POST /nodes/{id}/reload, POST /nodes/reload) are kept for native API
users. MCP callers should use node_stop + node_start (partial) or
close/open project (full restart) instead.
A heredoc (<<<) closes stdin at once, so websocat dropped the WebSocket
before the device's reply arrived. Add --no-close to the node_console usage
examples and the returned command field so the connection stays open while
output is read.
Token revocation is a strict version check (token_data.token_version !=
user.token_version). create_access_token defaults token_version to 0, so the
short-lived JWTs minted for the console WebSocket URL (nodes) and the download
URLs (symbols, links) carried ver=0. Any user who had logged out at least once
(token_version >= 1, e.g. the default admin) got tokens rejected as "revoked"
on first use.
e433991cf fixed this in _resolve_token's API-key branch but missed these three
independent minting sites. Now resolve token_version during _resolve_token (the
JWT branch decodes it, the API-key branch reads user.token_version), carry it
through gns3_ctx, and pass it at every minting call.
_resolve_token generated a temp JWT with a hardcoded ver=0 after
validating the API key. Users who had logged out at least once
(token_version >= 1) would hit "Token has been revoked" 401 on
every MCP tool call, because the REST auth chain rejects ver=0
when the user's token_version no longer matches.
Fix: pass the user's actual token_version to create_access_token
so the temp JWT carries the correct ver claim.
The name device_command_run was ambiguous and easily confused with
device_config_send. device_show_run makes the read-only intent explicit,
forming a clear pair: config_send (write) vs show_run (read).
- Tool description and param schema now use 'commands' (matching ExecuteMultipleDeviceCommands)
- Updated error message in handler
- Clarified in docstring that this is read-only; use device_config_send for config changes
template_list was annotated as dict[str, Any] but _run_handler_sync always
returns a list envelope ([{"type":"text",...}]). Other tools use
list[dict[str, Any]] consistently. This caused a Pydantic dict_type
validation error on the client.
When MCP client authenticates with API key, _resolve_token now
returns a newly generated JWT. This JWT is stored in the ContextVar
and used by all subsequent tool handler API calls - zero extra bcrypt.
- Expose optional 'fields' parameter to AI via tool description
- List all available node fields in the parameter description
- Mention inherited template_id in batch mode
- Batch mode now inherits top-level template_id as default per-node
- Both single and batch modes filter response to minimal fields by default
(node_id, name, node_type, status, console)
- Optional 'fields' parameter overrides the default field set
_ jw t_username_var set in _resolve_token for both JWT and API key auth.
Passed to handlers via gns3_ctx['jwt_username']. No raw key exposure,
no fake-user fallback.
config_tools_nornir expects config_commands, while
display_tools_nornir and vpcs_tools_netmiko expect commands.
Render template now uses the correct field name.
- Add optional 'template' param with Jinja2 syntax
- Each device entry can use 'vars' dict instead of 'config_commands'
- Template rendered per device, merged with existing commands
- Rendering errors returned inline for AI self-correction
- Each tool accepts either node_id (single) or node_ids (batch)
- Batch mode runs actions in parallel via ThreadPoolExecutor
- Useful for starting/stopping nodes by topology region