Replace the `xpra=6.4*` version clamp on the apt-get install command
line with APT pinning via /etc/apt/preferences.d/pin-xpra.
The previous specifier stopped resolving once xpra 6.5 was released:
the xpra metapackage was pinned to 6.4 while its sub-packages
(xpra-client, xpra-server, xpra-codecs, ...) were unconstrained and
defaulted to 6.5, so apt could not satisfy the dependency graph and
the "Build Docker images" action failed.
Pinning all xpra* packages at the preferences level constrains the
whole set consistently (xpra-html5 is handled separately since it
follows a different version scheme, locked to v19). Blocking every
other version with priority -1 ensures that, if the pinned version
ever disappears from the repository, apt fails loudly instead of
silently upgrading to the latest release.
FixesGNS3/gns3-registry#1044
- Move fastmcp from core requirements.txt to mcp-requirements.txt
- Add MCP_AVAILABLE feature flag in agent/__init__.py (graceful degradation)
- Guard MCP imports/registration in server.py and tasks.py
- Replace ai-copilot/mcp/ai-support extras with single ai-features extra
- Add stub MCP routes returning 501 when MCP is not installed
- Add gns3server-uninstall-ai-features CLI command
- Remove old gns3server-uninstall-ai-copilot command
- Update all error messages and docs to reference ai-features
Closes#2794
- New config: Controller.jwt_refresh_token_expire_minutes (default 30 days)
- New endpoint: POST /v3/access/users/refresh (public, unauthenticated)
- Login/authenticate responses now include refresh_token
- AuthService: _create_token helper, create_refresh_token, get_token_data
now parses type claim (token_use) for token classification
- Security: refresh tokens rejected on HTTP + WebSocket access paths;
/refresh strictly requires type=='refresh'
- Logout works for free via existing token_version mechanism
- Tests: 9 new TestRefreshToken cases, all passing; 34 existing tests
still pass (no regressions)
The controller endpoint received name via TemplateUsage but never
passed it to add_node_from_template, causing the name parameter to
be silently ignored. name is optional - if omitted the template's
default_name_format is used.
The name device_command_run was ambiguous and easily confused with
device_config_send. device_show_run makes the read-only intent explicit,
forming a clear pair: config_send (write) vs show_run (read).
- Tool description and param schema now use 'commands' (matching ExecuteMultipleDeviceCommands)
- Updated error message in handler
- Clarified in docstring that this is read-only; use device_config_send for config changes
template_list was annotated as dict[str, Any] but _run_handler_sync always
returns a list envelope ([{"type":"text",...}]). Other tools use
list[dict[str, Any]] consistently. This caused a Pydantic dict_type
validation error on the client.