POST /appliances/{id}/install replied 204 with an empty body, so the MCP
appliance_install tool crashed with 'Expecting value: line 1 column 1'
while the template had actually been created. The route now returns the
created template (201, response_model=schemas.Template), _create_template
propagates it, and the MCP handler parses the body defensively so an
empty reply degrades to a plain success message.