The reconnect-blank-screen bug: when sr_cli exited (quit / idle timeout /
crash) the while-true wrapper restarted it mid-session with no client
attached, so its startup CPR probe (\e[6n) went unanswered and the TUI
degraded/blocked. On reconnect lazy_started=True skipped recreation, so the
client saw a blank screen.
Fix: drop the while-true wrapper. Now when the CLI exits, the exec pty
closes (EOF), the broadcast task ends, and the next client connection
detects the dead upstream via _upstream_alive() and recreates the exec —
with a terminal attached, so CPR is answered. A live exec is reused
(just a Ctrl-L redraw).
_LazyExecTelnetServer is extracted from a closure to module level so the
reconnect/recreate logic is unit-testable. Add 9 tests covering
_upstream_alive states and the recreate-on-death / reuse-if-live /
close-half-dead-writer / no-while-true behaviors.
Full Docker suite (120) passes.
25 tests covering:
- Docker.create_node factory: selects VendorDockerVM iff console_type ==
docker_exec, DockerVM otherwise (including telnet/ssh/vnc/http/none/spice)
- GNS3_* env parsing: SKIP_INIT, INTERFACE_NAMES, CONSOLE_CMD (single and
multiline), defaults
- create(): init.sh skipped under GNS3_SKIP_INIT, prepended otherwise;
GNS3_MAX_ETHERNET follows the interface rename; /etc/network mount dropped
under SKIP_INIT (and host skeleton dir removed) but kept without it
- _add_ubridge_connection: move_to_ns targets the renamed interface
(mgmt0) or falls back to eth{N}
- start(): docker_exec console dispatch + SKIP_INIT volume bridge + permission
fix; without SKIP_INIT the vendor passes are skipped
- _fix_permissions: skips dead/missing containers (no restart), targets
/gns3volumes bind-mount paths
- _setup_skip_init_volumes: runs the docker exec bridge script
- _cleanup_console_resources: closes the exec pty writer
Full Docker suite (111) and compute suite (395) pass — the four hook
extractions in DockerVM introduce no regressions.
The _connect_nio thread-pool optimisation (send_batch_sync) targeted
node-start performance, but start_all already runs at concurrency=3
(by design, to avoid overwhelming the host). It also introduced a
Python 3.13 incompatibility (trsock.setblocking forbidden) that
prevented docker nodes from starting. Since node-start is not the
target of this branch (project-open link creation is), revert to the
simple per-command async _ubridge_send.
The project-open batch NIO dispatch (create_batch_nios) is unaffected —
it never called _connect_nio (nodes aren't started during open).
Replace the 3-5 sequential await _ubridge_send calls in _connect_nio
with a single run_in_executor batch. The batch holds the node-level
asyncio Lock to prevent interleaving with async sends, then uses the
hypervisor's new send_batch_sync method which does blocking socket
sendall/recv inside the thread pool. Different nodes' batches now
run in true OS-thread parallelism rather than serialising through
the asyncio event loop between every command.
- ubridge_hypervisor.send_batch_sync: blocking batch send using
the underlying socket from the asyncio transport, protected by
threading.Lock.
- _connect_nio: builds command list (add_nio_udp, start_capture,
bridge start, reset_packet_filters, add_packet_filter) and
dispatches to the default executor.
Docker node stop took ~5s every time. The stop API grace period
(params t=5, unchanged since 2015) was always exhausted: the business
process (often an interactive shell) ignores SIGTERM, and GNS3 doesn't
depend on graceful shutdown — _fix_permissions and /gns3volumes already
persist container state before stop() is called.
Use POST /containers/{id}/kill (SIGKILL, zero delay) instead of stop.
The 409 (container already stopped) replaces the previous 304 handling
for the race where the container exits between the state check and the call.
t=5 traced to commit 33edbefa3 (2015-10-14) "Docker cleanup and
improvements" — introduced with no recorded rationale.
The condition 'state != "stopped" or state != "exited"' is a tautology,
so the state check was a no-op and a stop request was sent even for a
container that had already exited.
_get_container_state() never returns "stopped" (only "running",
"paused" or "exited"), so the intended negation of the condition used in
_fix_permissions() requires 'and', not 'or' (De Morgan's law).
Added a regression test asserting no stop query is issued for an
already-exited container.