The cloud node offered the kernel datapath's host-side interfaces —
node anchors (gv/gq/gi/gd/gx/gp), switch cascade veth ends (gs) and
cross-compute VXLAN devices (gvl) — in its interface list and even
pre-filled them as ports on a freshly created cloud: none of them is
flagged special and only "gns3*" names were filtered. These interfaces
belong to the link or node that created them for the project's whole
lifetime, so bridging a cloud to one would race its owner.
Add is_kernel_datapath_interface() next to the naming contract in
utils/kernel_anchor.py: exact-shape matching (prefix plus its
fixed-length id-derived tail), so a user interface that merely starts
with "gv" is never swallowed. The cloud keeps managed names out of its
host-interface list and default ports mapping, while saved mappings
keep working (the existence checks still see the full interface list).
NAT now includes an 'interfaces' field in its response, filtered to
contain only the mapped NAT interface (virbr0 on Linux, vmnet8 on
macOS/Windows). This lets connected nodes discover the NAT subnet
and gateway address without needing to list all host interfaces.
The field format mirrors Cloud.asdict(): name, type, special, and
ip_addresses list (both IPv4 and IPv6).
Each host interface surfaced by the cloud node now reports:
- ip_addresses: every IPv4 and IPv6 address (previously only a single
IPv4 was collected internally and then dropped before the response)
- status / speed / mtu / flags: operational state and link attributes
sourced from psutil.net_if_stats(), with flags normalized to a list
The legacy ip_address / netmask / mac_address fields are preserved so
existing callers (compute link detection, GNS3 VM, VMware, has_netmask)
keep working. The new fields travel through the existing interfaces
payload that the controller forwards verbatim, so no controller-side
change is required and the PUT / ports_mapping flow is unaffected.