Review feedback: 3.1 is still in alpha and the GNS3 VM ships a matching
uBridge, so a hard minimum is simpler than a version-based degrade path,
and it also covers Docker endpoints and the builtin Ethernet switch,
which never went through the anchor probes. Raise minimum_required_version
to 1.3.1 and drop supports_kernel_datapath and its uses; the relay
fallback for capability problems (no CAP_NET_ADMIN) is unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
uBridge 1.2.3 already has the tap module, so the persistent-TAP probes
(_probe_persistent_taps on the node, probe_tap_support and siblings for
/capabilities) pass on it. QEMU, Dynamips and VPCS nodes then anchor on
TAPs and the controller builds kernel links that need 1.3.x commands:
kernel markers and the eBPF tc modes (1.3.0) and per-interface kernel
captures (`capture stop_kernel <ifc>`, 1.3.1). On 1.2.3 a MikroTik CHR
node sent frames but never got DHCP past DISCOVER/OFFER, and stopping
a capture failed with "Bad number of parameters".
Add Hypervisor.supports_kernel_datapath (version >= 1.3.1) and refuse
older builds in the node-side probe and the four anchoring capability
probes (tap, iol tap, bridge tap, vxlan). The existing fallback then
applies: nodes keep the legacy relay datapath with the usual warning,
which now names the installed version, and links stay on the relay.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Drop the platform-specific floor (0.9.12 darwin / 0.9.14 others) in
favour of a single 1.2.0 minimum. This server now relies on features
only present in recent uBridge builds: the AF_UNIX control channel
(-U / SO_PEERCRED), the marker (mark) filter, and the brctl-backed
builtin Ethernet Switch. Removes the now-unused sys import left behind
by the dropped darwin branch (target is Linux-only).
Use the node id (UUID) instead of an incrementing counter for the unix
control socket name, so each socket identifies its owning node at a glance
(one ubridge per node => node_id is unique). Falls back to the counter only
when no node id is supplied. A single UUID fits sun_path's 107-byte cap
(~69 bytes), so no project_id is needed.
start() now checks whether ubridge exited immediately after launch. An
old ubridge build that does not understand -U exits with a non-zero code
right away; surface the reason from ubridge.log instead of waiting for
connect() to time out 10s later with a confusing "couldn't connect" error.
Add ubridge_control_transport to [Server] config (default "tcp", fully
backward compatible). Selecting "unix" switches the uBridge hypervisor
control channel from the unauthenticated TCP listener (-H) to an AF_UNIX
socket (-U) authenticated in-kernel via SO_PEERCRED.
- UBridgeHypervisor: supports both socket_path (AF_UNIX) and host/port
(TCP); a new `endpoint` property unifies log/error strings for both
- Hypervisor: unix mode allocates a short socket path under a 0700
private runtime dir and unlinks it on stop; tcp mode restores the
original getaddrinfo ephemeral-port allocation
- base_node: reads the transport from config and passes host through
- schemas/config.py + config_samples/gns3_server.conf: new option
Default deployments are unchanged. "unix" requires a ubridge build that
understands -U.